A BESS unit is a self-contained battery energy storage cabinet with its own inverter, battery and controls, ready to connect to a load, a generator or the grid. For most commercial and remote-site projects the choice comes down to format and power level: the VE30 K3-60 is a compact 30 kW all-in-one unit with forklift access that moves easily between sites, while the MG100K-207 is a 100 kW outdoor cabinet built for a fixed commercial or microgrid position. Both use LiFePO4 batteries with a design life of 10 years or more.
VE30 K3-60 vs MG100K-207: datasheet comparison
The two units are not scaled versions of each other. They target different deployment models. The VE30 K3-60 arrives as one pre-wired enclosure weighing 1.3 t, light enough to fit four units in a 20 ft container. The MG100K-207 stays in place as a fixed outdoor cabinet sized for permanent installation, with a higher battery voltage and a 50 kW DC/DC converter dedicated to solar charging.
| Spec | VE30 K3-60 | MG100K-207 |
|---|---|---|
| Rated output | 30 kW | 100 kW |
| AC output (standard) | 3L+N+PE, 400 V, 50/60 Hz | 304 to 437 V, 50 Hz |
| Peak power | 37.5 kW for 10 s | 120 kW for 60 s |
| Battery capacity | 61.44 kWh LiFePO4 | 207 kWh LiFePO4 |
| Battery voltage | 51.2 V (up to 12 modules) | 739.2 V |
| Max inverter efficiency | 97.8 % | 98 % |
| Solar input | 4 × 4 kW MPPT | 1 MPPT route, 50 kW DC/DC |
| Max charge/discharge current | 100 A / 100 A | 192 A / 192 A |
| Enclosure protection | Confirm in quotation | IP54 |
| Monitoring | Confirm in quotation | 4G included |
| Weight | 1.3 t | Confirm in quotation |
| Container loading | 4 per 20 ft, 8 per 40 ft | Confirm in quotation |
| Certifications | IEC 62619, CE, UN38.3 | Confirm in quotation |
The VE30 K3-60 runs off-grid or grid-tied and can run in parallel with a diesel generator, including the customer’s own genset. The MG100K-207 is specified for peak shaving, solar self-consumption, microgrids and commercial backup. The standard voltage and frequency above are not fixed: as the factory, we configure either unit for your country, for example 120/240 V, 208 V or 480 V at 60 Hz in North America, and the configuration is confirmed on the quotation.
VE30 K3-60: the mobile, all-in-one option
The VE30 K3-60 packs a 30 kW inverter, 61.44 kWh battery and four MPPT solar channels in one enclosure.
The VE30 K3-60 fits projects where the load moves, the site is temporary, or the crew needs to deploy fast without a crane or a slab. At 1.3 t and with four units per 20 ft container, it travels well by road or sea. Rated output of 30 kW with a 37.5 kW peak for 10 seconds gives headroom for short starting surges from smaller equipment such as compressors and pumps. The four independent 4 kW MPPT channels mean the unit can take solar directly on-site without a separate charge controller, which matters for telecom sites and construction compounds running mixed PV and grid power.
Typical use cases based on the datasheet: rental fleets rotating a unit between job sites, EPCs building out a chain of telecom towers one site at a time, event organizers who want quiet battery-only operation at low load, and emergency teams that need a unit they can handle with a forklift. To see how this format stacks up against a diesel genset, read 30 kW mobile battery storage vs diesel generators. For projects spanning several remote towers, our guide on solar-battery power for telecom sites walks through the sizing logic in more detail.
MG100K-207: the outdoor cabinet for fixed commercial sites
The MG100K-207 is built as a permanent outdoor cabinet, rated 100 kW with 207 kWh of LiFePO4 storage and IP54 protection.
The MG100K-207 is the right format when the site is fixed and the load is bigger: solar farms needing firming capacity, industrial microgrids, EV charging hubs or large commercial buildings running peak shaving. At 739.2 V, the battery pack runs at a higher voltage than the VE30 K3-60, which keeps current lower for the same power and suits a permanent switchboard connection rather than a plug-and-play trailer link. The unit’s 98 % maximum inverter efficiency and 120 kW peak rating for 60 seconds give it headroom for short surges from chillers, lifts or large motor loads without oversizing the whole system.
The IP54 enclosure and built-in 4G monitoring target unattended outdoor placement: a solar farm compound, an industrial yard or a commercial site, subject to local standards and permits. Because the battery voltage and DC/DC converter are sized for one dedicated MPPT route at 50 kW, this unit pairs well with a fixed PV array rather than multiple small arrays scattered across a site. Before you commit to either format, our step-by-step guide on sizing a commercial energy storage system walks through matching battery capacity to a building’s load profile.
Sizing logic: power, capacity or both?
Choosing between the two units is rarely about raw kW alone. Three questions decide it, based on the specs above:
- Peak load and surge duration. If your site needs to start a motor or compressor for a few seconds above continuous demand, check the peak rating window: 37.5 kW for 10 s on the VE30 K3-60 versus 120 kW for 60 s on the MG100K-207. A longer surge window matters more for pumps or refrigeration compressors with slow start cycles.
- Runtime needed at full load. Divide the battery capacity by your continuous kW demand for a rough runtime. A VE30 K3-60 at 61.44 kWh running a 20 kW average load gives roughly 3 hours before recharge; an MG100K-207 at 207 kWh running a 60 kW average load gives roughly 3.4 hours, before losses. Match this against your solar input or genset backup, not against the battery alone.
- Logistics and site type. If the project is temporary, multi-site, or needs fast redeployment, the VE30 K3-60’s container loading (4 per 20 ft) and smaller footprint win. If the project is a single fixed installation with a concrete pad and permanent grid or solar tie-in, the MG100K-207’s IP54 cabinet and 4G remote alerts suit unattended operation in a long-term microgrid plan.
For mixed scenarios, such as several remote sites needing moderate power alongside one central site needing more, one option is a few VE30 K3-60 units at the satellite locations and an MG100K-207 cabinet at the hub, so each site gets power matched to its real load.
What We Need to Quote Your BESS Project
Send these details with your request and we can quote the right BESS unit:
- Continuous load (kW) and any motor or compressor surge loads with their starting kVA
- Required autonomy or runtime at full load, and whether solar, grid or a generator will recharge the battery
- Site voltage and frequency (single-phase or three-phase, 50 Hz or 60 Hz)
- Ambient temperature range and whether the unit sits outdoors, indoors or under a shelter
- Number of units needed and target delivery location (port or site address)
- Certification your inspector or utility requires (UL, CSA, CE, local grid-tie rules). UL or CSA certification is available on request for the chosen model
These six points let us confirm dimensions, weight, container loading and lead time without extra back-and-forth. Scaling up to a larger hybrid system with diesel backup? Our checklist on preparing a hybrid ESS quote request covers the same ground for bigger installations.
Ready to Spec Your BESS Unit?
Share your load profile, site conditions and target delivery date. We will confirm whether the 30 kW VE30 K3-60 or the 100 kW MG100K-207 fits your project, along with a price and delivery estimate. Request a quote.
Frequently asked questions
What if my site needs more than 100 kW?
The datasheets of these two units do not cover multi-unit paralleling. Send your total peak load and daily energy use, and we will confirm in the quotation whether several units can share the site or whether a larger hybrid system fits better.
Do these units include solar input?
The VE30 K3-60 has four 4 kW MPPT solar channels built in (16 kW total). The MG100K-207 has one MPPT route rated 50 kW on its bidirectional DC/DC converter, sized for larger PV arrays feeding a fixed site.
What certifications apply to the battery in these BESS units?
The VE30 K3-60 battery is certified to IEC 62619, CE and UN38.3. The MG100K-207 datasheet lists IP54 enclosure protection and 4G remote monitoring; its certification package for your destination market is confirmed in the quotation. UL or CSA certification is available on request for the model you choose.
Which unit suits a telecom tower or remote microgrid better?
For a single tower or small site, the 30 kW VE30 K3-60 is usually enough and keeps logistics simple. For a cluster of towers, a mine camp or a commercial microgrid with heavier loads, the 100 kW MG100K-207 reduces the number of cabinets needed per kW installed.